The Clima Sensor D serves for the measurement of environmental data.
|
| Wind speed : Measuring range : 1...40 m/s Resolution : 0,1 m/s Accuracy : ±0,5 m/s or ±5 % of measuring range |
Precipitation : Measuring range : Precipitation Yes / No Resolution : Drizzle Switch-off delay : approx. 2 minutes |
|
| Temperature : Measuring range : -20...+60°C Resolution : 0,1 K Accuracy : ±0,15°C at 0°C |
Relative humidity : Measuring range : 0...100% Resolution : 1% Accuracy : ±3% (10 ... 90%) |
|
| Brightness : (f. South, East, West) Measuring range : 0...150.000 Lux Resolution : 100 Lux Accuracy : ±10% of measuring value |
Twilight : Measuring range : 0...250 Lux Resolution : 1 Lux Accuracy : ±10% of measuring value |
|
| Seriel output : Interface : RS485 / RS422 Protocol : ASCII Mode : Full / Halfduplex Baudrates : 1200...19200 bd Output parameter : Environmental data, housing temperature, date, time, sensor status, checksum |
Analog outputs : Signals : max. 8x 0...10 V (incl. precip. : 0 V or 10 V ) Output : Real time values, running means Resolution : 16 bit Rate : Update 10 ms |
|
| Housing : Material : Lexan (Polycarbonate, UV-resistant) Mounting : onto tube Ø 35...50 mm Dimensions : Ø 130 x 430/335/310/215 mm Weight : 1,5 kg (complete version) Connection : 10 m cable LiYcY 16x 0,14 mm² |
Power : 16 ... 28V DC or 24 V AC Consumption : max. 150 mA Current condensation protection : 600 mA |
Possible versions :
| Order-Nr. | Wind speed | Precipitation | Brightness | Temperature | Air humidity | DCF77 receiver |
| 4.9101.00.061 | x | x | x | |||
| 4.9111.00.061 | x | x | x | x | x | |
| 4.9100.00.061 | x | x | x | x | ||
| 4.9110.00.061 | x | x | x | x | x | x |